???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: https://tede.ufam.edu.br/handle/tede/6304
???metadata.dc.type???: Dissertação
Title: Emprego de EPS reciclado em blocos vazados de concreto para otimização do conforto térmico das edificações
???metadata.dc.creator???: Gonçalves, Paulo José Simão 
???metadata.dc.contributor.advisor1???: Vasconcelos, Raimundo Pereira de
???metadata.dc.contributor.referee1???: Araújo, Valdete Santos de
???metadata.dc.contributor.referee2???: Melo Filho, João de Almeida
???metadata.dc.description.resumo???: A preservação dos recursos naturais e a implantação do fator sustentável na concepção de projetos são duas das principais preocupações observadas atualmente por pesquisadores e engenheiros em todo mundo. A pesquisa desenvolvida buscou viabilizar uma nova elaboração de concretos que incorporassem estas diretrizes ao inserir o poliestireno expandido, oriundo da reciclagem mecânica, em substituição parcial ao agregado graúdo tradicional empregado no estado do Amazonas. Inicialmente, realizou-se a caracterização físico-química dos componentes envolvidos com o intuito de verificar o emprego destes na produção de blocos vazados. Após esta fase, obteve-se a dosagem experimental por meio da associação do Modelo de Empacotamento Compressível com a metodologia adaptada de Tango para os quatro tipos de concretos produzidos (com teores de substituição volumétrica de 0, 5, 10 e 15% do agregado graúdo por EPS reciclado), definindo um fator a/c igual a 0,5 para todos eles. Os ensaios executados para verificação das propriedades físicas e mecânicas seguiram as diretrizes da NBR 12118:2013, e resultaram em duas classificações quanto à resistência à compressão encontrada: os blocos referenciais (0%) e com 5% de substituição da brita pelo EPS reciclado (definido como o limite para empregar esta troca segundo a NBR 6136:2014) poderiam ser direcionados para fins estruturais, enquanto que os com 10 e 15% de substituição não atenderam a resistência mínima de aceitação. A respeito da análise térmica, verificou-se que os blocos atenderam parcialmente a NBR 15575-4:2013, necessitando de adequações para garantir o nível de desempenho mínimo exigido por esta norma. Os confortos térmicos proporcionado pelos blocos referenciais e com 15% de EPS apresentaram resultados semelhantes em função da transmitância térmica que, juntamente com as distintas temperaturas radiantes, equipararam os fluxos médios de calor em ambos exemplares. Contudo, no horário de pico da temperatura ambiente, verificou-se o maior atraso e inércia térmica na alvenaria com EPS reciclado, reduzindo da transmissão de calor entre as faces das paredes.
Abstract: The natural resources preservation and implementation of sustainable factor in projects are two of main concerns obeserved currently by researchers and engineers resident around world. The developed research seeked to make feasiable new concretes that incorporate these guidelines inserting expanded polystyrene, from mechanical recycling, in partial replacement of traditional coarse aggregate used in Amazonas. Firstly was carried out a physicochemical characterization in involved components to verify their uses on production of hollow concrete blocks. After that, the experimental dosage was obtained in association of Compressible Packaging Model with Tango´s adapted methodology for four concretes produced (with content ratios of 0, 5, 10 and 15% as partial volumetric replacement of coarse aggregate by recycled EPS) and w/c ratio of 0,5 was found for all concretes. The tests performed procedures to check physical and mechanical properties followed the NBR 12118:2013, and resulted in two classifications in terms of compressive strenght: referencial (0%) and 5% gravel’s parcial replacement by recycled EPS (defined as limit for employing this exchange according to NBR 6136:2014) attested their uses for structural applications, while 10 and 15% EPS’ partial replacement couldn´t be used because their compressive strenght were lower than minimum acceptance strenght. Regarding thermal analysis, it was verified that all blocks partially attented NBR 15575-4:2013, necessitating adjustments to ensure the minimum perfomance level required for that standard. The thermal comfort provided by referential blocks and blocks with 15% of recycled EPS presented similar results as a function of thermal transmittance and different radiant temperatures, became similar average heat flows in both specimens. However, at times when environment peak temperature were recorded, it was verified greater delay and thermal inertia in the masonry with recycled EPS, reducing heat transmition through the walls.
Keywords: Concreto leve
Materiais alternativos
Termografia
Alvenaria
Lightweight concrete
Alternative materials
Thermography
Masonry
???metadata.dc.subject.cnpq???: ENGENHARIAS: ENGENHARIA CIVIL
Language: por
???metadata.dc.publisher.country???: Brasil
Publisher: Universidade Federal do Amazonas
???metadata.dc.publisher.initials???: UFAM
???metadata.dc.publisher.department???: Faculdade de Tecnologia
???metadata.dc.publisher.program???: Programa de Pós-graduação em Engenharia Civil
Citation: GONÇALVES, Paulo José Simão. Emprego de EPS reciclado em blocos vazados de concreto para otimização do conforto térmico das edificações. 2018. 147 f. Dissertação (Mestrado em Engenharia Civil) - Universidade Federal do Amazonas, manaus, 2018.
???metadata.dc.rights???: Acesso Aberto
???metadata.dc.rights.uri???: http://creativecommons.org/licenses/by-nc-nd/4.0/
URI: https://tede.ufam.edu.br/handle/tede/6304
Issue Date: 6-Feb-2018
Appears in Collections:Mestrado em Engenharia Civil

Files in This Item:
File Description SizeFormat 
Dissertação_Paulo J. S. Gonçalves.pdf7.67 MBAdobe PDFThumbnail

Download/Open Preview


This item is licensed under a Creative Commons License Creative Commons