???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: https://tede.ufam.edu.br/handle/tede/7605
???metadata.dc.type???: Dissertação
Title: Efetividade do clareamento de consultório utilizando peróxido de hidrogênio 6% com fotoativação LED Violeta: ensaio clínico randomizado
???metadata.dc.creator???: Martinho, Paulo Victor de Araújo 
???metadata.dc.contributor.advisor1???: Silva, Luciana Mendonça da
First advisor-co: Martins, Leandro de Moura
???metadata.dc.contributor.referee1???: Queiroz, Adriana Corrêa de
???metadata.dc.contributor.referee2???: Giorgi, Maria Cecília Caldas
???metadata.dc.description.resumo???: O clareamento dentário, apesar de ter se tornado muito popular entre os pacientes, ainda possui como reação comum à sua prática a sensibilidade dentária (SD). O uso do gel clareador de baixa concentração vem sendo proposto para diminuição dessa sensibilidade com associação a fontes de luz, porém ainda não há consenso quanto à sua efetividade. Este estudo teve como objetivo avaliar a efetividade do peróxido de hidrogênio (PH) 6% com fotoclareador LED violeta, pela técnica de clareamento de consultório. Foram selecionados 31 pacientes para um ensaio clínico randomizado e duplo-cego (avaliador e estatístico) que seguiu um delineamento de boca-dividida criando (2 grupos): PH6LED submetido à técnica de clareamento de consultório com PH 6% associado ao uso do fotoclareador LED violeta; PH6 submetido à técnica com PH 6%, sem fotoativação. Foram realizadas 2 sessões de clareamento de 33 minutos em ambos os grupos, com a avaliação da cor feita de forma objetiva (espectrofotômetro) e subjetiva (guia visual de cor); realizadas ao início, antes da segunda sessão, 7 dias e 30 dias após o final do tratamento clareador. A mensuração da sensibilidade foi feita através da Escala Numérica de 5 pontos (NRS) e da Escala Visual Analógica (VAS). Os resultados demonstraram maior efetividade do clareamento para o grupo PH6LED na avaliação subjetiva com a escala Vita Bleachedguide (PH6LED ∆SGU= 2.8±1.2 e PH6 ∆SGU= 2.6±1.2; p=0.014) e semelhança estatística na objetiva (PH6LED ∆E= 10.3±12.2 e PH6 ∆E= 9.9±8.6) e intensidade da sensibilidade dentária (PH6LED 0.23±0.39 e PH6 0.32±0.59). O risco absoluto de SD (registrada pelo menos uma vez pelos pacientes) foi igual para ambos os grupos. O nível de significância adotado foi de 5%. O uso do fotoclareador LED não resultou em maior efetividade e tampouco aumentou a sensibilidade pós clareamento.
Abstract: Tooth whitening, although it has become very popular among patients, still has as common reaction to its practice tooth sensitivity (DS). The use of low concentration whitening gel has been proposed to decrease this sensitivity associated with light sources, but there is still no consensus as to its effectiveness. The objective of this study was to evaluate the effectiveness of 6% hydrogen peroxide (PH) with violet LED photoclarger by the office whitening technique. Thirty-one patients were selected for a randomized, double-blind clinical trial (evaluator and statistic) that followed a split-mouth design creating (2 groups): PH6LED subjected to 6% PH office bleaching technique associated with the use of LED photobleacher Violet; PH6 submitted to the technique with 6% PH, without photoactivation. Two 33-minute bleaching sessions were performed in both groups, with objective (spectrophotometer) and subjective (visual color guide) color evaluation; performed at the beginning, before the second session, 7 days and 30 days after the end of the bleaching treatment. Sensitivity was measured using the 5-point Numerical Scale (NRS) and the Visual Analog Scale (VAS). The results showed greater whitening effectiveness for the PH6LED group in the subjective evaluation with the Vita Bleachedguide scale (PH6LED ∆SGU = 2.8 ± 1.2 and PH6 ∆SGU = 2.6 ± 1.2; p = 0.014) and statistical similarity in the objective (PH6LED ∆E = 10.3 ± 12.2 and PH6 ∆E = 9.9 ± 8.6) and tooth sensitivity intensity (PH6LED 0.23 ± 0.39 and PH6 0.32 ± 0.59). The absolute risk of DS (recorded at least once by patients) was equal for both groups. The adopted significance level was 5%. The use of LED photoclarger did not result in greater effectiveness or enhanced the sensitivity after bleaching.
Keywords: Dentes - Clareamento
Peróxido de hidrogênio
???metadata.dc.subject.cnpq???: CIÊNCIAS DA SAÚDE: ODONTOLOGIA
???metadata.dc.subject.user???: Clareamento dental
Efetividade
Peróxido de hidrogênio
Language: por
???metadata.dc.publisher.country???: Brasil
Publisher: Universidade Federal do Amazonas
???metadata.dc.publisher.initials???: UFAM
???metadata.dc.publisher.department???: Faculdade de Odontologia
???metadata.dc.publisher.program???: Programa de Pós-graduação em Odontologia
Citation: MARTINHO, Paulo Victor de Araújo. Efetividade do clareamento de consultório utilizando peróxido de hidrogênio 6% com fotoativação LED Violeta: ensaio clínico randomizado. 2019. 63 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Amazonas, Manaus, 2019.
???metadata.dc.rights???: Acesso Aberto
URI: https://tede.ufam.edu.br/handle/tede/7605
Issue Date: 9-Dec-2019
Appears in Collections:Mestrado em Odontologia

Files in This Item:
File Description SizeFormat 
Dissertação_PauloVictorMartinho_PPGO.pdf1.28 MBAdobe PDFThumbnail

Download/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.