???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: https://tede.ufam.edu.br/handle/tede/7901
???metadata.dc.type???: Dissertação
Title: Estudo in vitro da quantidade do uso de pontas de ultrassom na eficiência da remoção de retentores metálicos
???metadata.dc.creator???: Paluch, Andréia di Paula Lira Bomfim 
???metadata.dc.contributor.advisor1???: Garrido, Ângela Delfina Bittencourt
???metadata.dc.contributor.referee1???: Martins, Leandro de Moura
???metadata.dc.contributor.referee2???: Chuí, Fabíola Mendonça da Silva
???metadata.dc.description.resumo???: O presente estudo avaliou in vitro a influência da quantidade de uso das pontas do ultrassom na eficiência da remoção de retentores metálicos. Cinquenta caninos superiores tratados endodonticamente receberam retentores metálicos fundidos cimentados com cimento fosfato de zinco. Os espécimes foram aleatoriamente randomizados em 5 grupos (n=10), de acordo com o protocolo de remoção a que foram submetidos: G I(controle) – Vibração ultrassônica utilizando ponta Remo C NOVA; G II- Vibração ultrassônica utilizando ponta Remo C usada 3 vezes ; G III- Vibração ultrassônica utilizando ponta Remo C usada 5 vezes; G IV- Vibração ultrassônica utilizando ponta Remo C usada 7 vezes; G V- Vibração ultrassônica utilizando ponta Remo C usada 9 vezes. O protocolo de vibração foi de 15 segundos em cada face (vestibular, palatina, mesial e distal) totalizando 1 minuto, sendo o aparelho de ultrassom JeTsonic Duo, escolhido para ser utilizado sob refrigeração. Todos os corpos-de-prova foram submetidos ao teste de tração na Máquina Universal de Ensaios a uma velocidade de tração de 1 mm/min até o completo desalojamento do retentor das paredes radiculares. A força de tração máxima necessária para a remoção do retentor intrarradicular foi registrada em Newtons. Os valores registrados foram submetidos à análise estatística através do programa Bioestat 5.0 e realizados testes de normalidade e testes paramétricos e não-paramétricos com nível de significância em 5%. Foram encontrados valores normais (Shapiro Wilk) e aplicado teste de variância ANOVA sendo encontrada diferença estatística (p.0051) P < 0,05. Foi realizado teste de TUKEY e verificado que os grupos 1 e 2 apresentaram as menores médias de força de tração (1-103N; 2- 104N) quando se utilizou ponta Nova e usada 3x e a maior média 190N quando a ponta foi usada 9X( grupo 5). Foi encontrada diferença estatística entre os grupos 1 e 5 (p<0,05) e grupos 2 e 5 (p<0,05), não sendo encontrado diferença nos outros grupos testados. O estudo ressalta a importância da renovação das pontas de ultrassom para otimizar a eficiência ultrassônica. Sendo uma ponta nova utilizada no máximo até 7 vezes.
Abstract: The present study evaluated in vitro the influence of the amount of use of ultrasound tips on the efficiency of removal of metallic retainers. Fifty endodontically treated upper canines received fused metal retainers cemented with zinc phosphate cement. The specimens were randomly randomized into 5 groups (n = 10), according to the removal protocol to which they were submitted: G I (control) - Ultrasonic vibration using Remo C NOVA tip; G II- Ultrasonic vibration using Remo C tip used 3 times; G III- Ultrasonic vibration using Remo C tip used 5 times; G IV- Ultrasonic vibration using Remo C tip used 7 times; G V- Ultrasonic vibration using Remo C tip used 9 times. The vibration protocol was 15 seconds on each face (buccal, palatal, mesial and distal) totaling 1 minute, being the ultrasound Jetsonic Duo, chosen for use under refrigeration. All specimens were subjected to tensile testing on the Universal Testing Machine at a tensile speed of 1 mm / min until complete removal of the root wall retainer. The maximum tensile force required for intrarradicular retainer removal was recorded in Newtons. The recorded values were submitted to statistical analysis using the Bioestat 5.0 program and normality tests and parametric and non-parametric tests were performed with a 5% significance level. Normal values were found (Shapiro Wilk) and ANOVA variance test was applied, with statistical difference (p.0051) P <0.05. TUKEY test was performed and it was verified that groups 1 and 2 had the lowest means of traction force (1-103N; 2- 104N) when using Nova tip and used 3x and the highest average 190N when used 9X tip (group 5). A statistical difference was found between groups 1 and 5 (p <0.05) and groups 2 and 5 (p <0.05), with no difference found in the other groups tested. The study highlights the importance of renewing the ultrasound tips to optimize ultrasonic efficiency. A new tip is used up to 7 times maximum.
Keywords: Ultrassom em odontologia
???metadata.dc.subject.cnpq???: CIÊNCIAS DA SAÚDE: ODONTOLOGIA
???metadata.dc.subject.user???: Retentores intraradiculares
Ultrassom
Resistência a tração
Pontas de ultrassom
Language: por
???metadata.dc.publisher.country???: Brasil
Publisher: Universidade Federal do Amazonas
???metadata.dc.publisher.initials???: UFAM
???metadata.dc.publisher.department???: Faculdade de Odontologia
???metadata.dc.publisher.program???: Programa de Pós-graduação em Odontologia
Citation: PALUCH, Andréia di Paula Lira Bomfim. Estudo in vitro da quantidade do uso de pontas de ultrassom na eficiência da remoção de retentores metálicos. 2020. 54 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Amazonas, Manaus (AM), 2020.
???metadata.dc.rights???: Acesso Aberto
???metadata.dc.rights.uri???: http://creativecommons.org/licenses/by-nc-nd/4.0/
URI: https://tede.ufam.edu.br/handle/tede/7901
Issue Date: 28-Feb-2020
Appears in Collections:Mestrado em Odontologia

Files in This Item:
File Description SizeFormat 
Dissertação_AndreeiaPaluch_PPGO.pdf1.74 MBAdobe PDFThumbnail

Download/Open Preview


This item is licensed under a Creative Commons License Creative Commons