???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: https://tede.ufam.edu.br/handle/tede/10088
Full metadata record
DC FieldValueLanguage
dc.creatorSouza, Emmina Lima da Cruz de-
dc.creator.Latteshttps://lattes.cnpq.br/3657543806964921eng
dc.contributor.advisor1Domingues, Wagner Jorge Ribeiro-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/2013104533801948eng
dc.contributor.referee1Arêas, Guilherme Peixoto Tinoco-
dc.contributor.referee2Puga, Guilherme Morais-
dc.date.issued2023-12-14-
dc.identifier.citationSOUZA, Emmina Lima da Cruz de. Efeitos agudos do exercício isométrico de handgrip na variabilidade da pressão arterial e na função e regulação cardiovascular em pessoas com hipertensão arterial sistêmica: um ensaio clínico cruzado. 2023. 109 f. Dissertação (Mestrado em Ciências do Movimento Humano) - Universidade Federal do Amazonas, Manaus, 2023.eng
dc.identifier.urihttps://tede.ufam.edu.br/handle/tede/10088-
dc.description.resumoA variabilidade da pressão arterial (VPA) é um importante preditor de mortalidade cardiovascular. Reduções na VPA em hipertensos podem minimizar o risco de eventos cardiovasculares. O exercício isométrico de handgrip (EIH) é eficaz na redução da pressão arterial (PA) em hipertensos e surge como estratégia alternativa de fácil aplicabilidade. Respostas cardiovasculares agudas após EIH predizem adaptações crônicas na regulação da PA. Contudo, os efeitos agudos do EIH na VPA são desconhecidos. Desta forma, o objetivo do estudo foi verificar o efeito agudo de uma sessão de exercício isométrico de handgrip na variabilidade da pressão arterial e na modulação autonômica cardíaca em pacientes hipertensos. Neste ensaio clínico randomizado crossover, participaram 45 pacientes, 62,3% mulheres, com idade 58,0 ± 10,5, randomizados (1:1) em condição EIH (n = 45) e SHAM (n = 45). Quando EIH realizaram 4 séries de 2 minutos de contração isométrica, com 1 minuto de intervalo, à 30% da contração máxima. Quando SHAM, seguiram as mesmas condições do EIH, utilizando bola antiestresse. A VPA foi avaliada pela variabilidade média real (VRM) e desvio padrão (DP) para pressão arterial sistólica (PAS) e diastólica (PAD), após sessão, pela MAPA (Dyna-MAPA, Cardios, Brasil). A modulação autonômica cardíaca (MAC) foi avaliada pela variabilidade da frequência cardíaca (VFC) nos domínios do tempo e frequência, nos momentos pré e pós EIH, por meio do monitor de frequência cardíaca Polar Vantage M2 com cinta Polar H10. Foi utilizado Teste T Independente e GEE para análise de comparação e análise de modelo, sendo adotado como significante valor de P<0,05. Não houve diferença significativa na VPA da PAS SHAM x EIH: VRM (8,96 mmHg ± 1,97 x 8,88 mmHg ± 2,04, p = 0,85), SD (13,17mmHg ± 3,68 x 13,07 mmHg ± 3,89, p = 0,89). A VPA da PAD não demonstrou diferenças significativas entre SHAM x EIH: VRM (7,13 mmHg ± 1,62 x 6,80 ± 1,21, p = 0,27), SD (10,27 mmHg ± 2,35 x 10,17 ± 2,10, p = 0,82). Na MAC, não houve interações tempos x grupo significativas no domínio do tempo: média dos intervalos RR (942,4 ms ± 117,5 x 947,16 ms ± 122,5, p = 0,77), SDNN (33,9 ms ± 20,1 x, 33,5 ms± 24,4 p =0,33), PNN50 (14,5% ± 18,2 x 14,6% ± 18,7, p = 0,28) e domínio da frequência: LF (0,078 un ± 0,026 x 0,071un ± 0,028, p = 0,25), HF (0,256 un ± 0,063 x 0,249 un ± 0,058, p = 0,49).Assim, uma sessão de EIH não causou efeitos significativos na VPA e na MAC em pacientes hipertensos.eng
dc.description.abstractBlood pressure variability (BPV) is an important predictor of cardiovascular mortality. Reductions in BVP in hypertensive patients can minimize the risk of cardiovascular events. The isometric handgrip exercise (IHE) is effective in reducing blood pressure (BP) in hypertensive patients and appears as an alternative strategy that is easy to apply. Acute cardiovascular responses after EIH predict chronic adaptations in BP regulation. However, the acute effects of EIH on BVP are unknown. Therefore, the objective of the study was to verify the acute effect of an isometric handgrip exercise session on blood pressure variability and cardiac autonomic modulation in hypertensive patients. In this randomized crossover clinical trial, 45 patients participated, 62.3% women, aged 58.0 ± 10.5, randomized (1:1) into IHE (n = 45) and SHAM (n = 45) conditions. When EIH performed 4 sets of 2 minutes of isometric contraction, with 1 minute interval, at 30% of the maximum contraction. When SHAM, they followed the same conditions as EIH, using an anti-stress ball. BVP was assessed by real mean variability (RMV) and standard deviation (SD) for systolic (SBP) and diastolic (DBP) blood pressure, after session, by MAPA (Dyna-MAPA, Cardios, Brazil). Cardiac autonomic modulation (CAM) was assessed by heart rate variability (HRV) in the time and frequency domains, in the moments before and after IHE, using the Polar Vantage M2 heart rate monitor with Polar H10 strap. Independent T Test and GEE were used for comparison analysis and model analysis, with a value of P<0.05 being adopted as significant. There was no significant difference in BVP of SBP SHAM x IHE: MRV (8.96 mmHg ± 1.97 x 8.88 mmHg ± 2.04, p = 0.85), SD (13.17mmHg ± 3.68 x 13 .07 mmHg ± 3.89, p = 0.89). DBP BVP did not demonstrate significant differences between SHAM x IHE: RMV (7.13 mmHg ± 1.62 x 6.80 ± 1.21, p = 0.27), SD (10.27 mmHg ± 2.35 x 10.17 ± 2.10, p = 0.82). In CAM, there were no significant time x group interactions in the time domain: mean RR intervals (942.4 ms ± 117.5 x 947.16 ms ± 122.5, p = 0.77), SDNN (33.9 ms ± 20.1 x, 33.5 ms± 24.4 p =0.33), PNN50 (14.5% ± 18.2 x 14.6% ± 18.7, p = 0.28) and domain of frequency: LF (0.078 un ± 0.026 x 0.071 un ± 0.028, p = 0.25), HF (0.256 un ± 0.063 x 0.249 un ± 0.058, p = 0.49). significant differences in BVP and CAM in hypertensive patients.eng
dc.description.sponsorshipFAPEAM - Fundação de Amparo à Pesquisa do Estado do Amazonaseng
dc.formatapplication/pdf*
dc.thumbnail.urlhttps://tede.ufam.edu.br/retrieve/75113/DISS_EmminaSouza_PPGCiMH.pdf.jpg*
dc.languageporeng
dc.publisherUniversidade Federal do Amazonaseng
dc.publisher.departmentFaculdade de Educação Física e Fisioterapiaeng
dc.publisher.countryBrasileng
dc.publisher.initialsUFAMeng
dc.publisher.programPrograma de Pós Graduação em Ciências do Movimento Humanoeng
dc.rightsAcesso Aberto-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subject.por
dc.subject.cnpqCIENCIAS DA SAUDE: EDUCACAO FISICAeng
dc.titleEfeitos agudos do exercício isométrico de handgrip na variabilidade da pressão arterial e na função e regulação cardiovascular em pessoas com hipertensão arterial sistêmica: um ensaio clínico cruzadoeng
dc.typeDissertaçãoeng
dc.contributor.advisor1orcidhttps://orcid.org/0000-0003-1638-6465eng
dc.creator.orcidhttps://orcid.org/0000-0002-2269-9188eng
dc.subject.userExercíciopor
dc.subject.userPressão arterialpor
dc.subject.userTreinamento de forçapor
dc.subject.userHipertensão arterial sistêmicapor
Appears in Collections:Mestrado em Ciências do Movimento Humano

Files in This Item:
File Description SizeFormat 
DISS_EmminaSouza_PPGCiMH.pdfDissertação3.07 MBAdobe PDFThumbnail

Download/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.