???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: https://tede.ufam.edu.br/handle/tede/3308
Full metadata record
DC FieldValueLanguage
dc.creatorFerreira, Lidiane Martins Moura-
dc.creator.Latteshttp://lattes.cnpq.br/0074391587319803por
dc.contributor.advisor1Braga, Neila de Almeida-
dc.date.available2013-10-22-
dc.date.issued2013-10-10-
dc.identifier.citationFERREIRA, Lidiane Martins Moura. Desenvolvimento de metodologia eletroanalítica para determinação de Cu, Fe e Zn em água empregando eletrodo de diamante dopado com boro. 2013. 94 f. Dissertação (Mestrado em Química) - Universidade Federal do Amazonas, Manaus, 2013.por
dc.identifier.urihttp://tede.ufam.edu.br/handle/tede/3308-
dc.description.resumoO cobre, ferro e zinco foram eletroanaliticamente quantificados utilizando a voltametria de redissolução anódica com onda quadrada (VRA/VOQ) com eletrodo de diamante dopado com boro (DDB). Para isso elaborou-se uma metodologia eletroanalítica onde os parâmetros voltamétricos foram otimizados para determinação dos metais. A determinação de todos os metais foi realizada em solução de KCl 1 mol.L-1 . Para a voltametria cíclica os metais apresentaram ambos os picos de oxidação e redução com características quase- reversíveis. Os parâmetros da VRA foram iguais para todos os metais excetuando-se os potenciais de deposição (Edep) que foram para o cobre -0,2 V, para o zinco -1,8 V e para o ferro -0,1 V, os tempos de deposição foram 180 s e o de equilíbrio 60 s. Quanto aos parâmetros da VOQ os mesmos foram diversificados para cada metal, para o cobre os valores de freqüência (f) e amplitude (a) foram respectivamente 60 Hz e 70 mV, pra o zinco 70 Hz e 80 mV já para o ferro 70 Hz e 90 mV. Após a otimização dos parâmetros foram construídas curvas analíticas para cada metal e calcularam-se os limites de detecção os quais resultaram em 0,005; 0,12 e 0, 169 ppm para o cobre, zinco e ferro respectivamente. A metodologia desenvolvida para detecção dos referidos metais foi aplicada em amostras de água retiradas do Igarapé do Quarenta localizado no distrito industrial de Manaus, as análises mostraram boa repetitividade e baixo erro quando comparados com os resultados obtidos por espectroscopia de absorção atômica.por
dc.description.abstractCopper, iron and zinc were electroanalytically quantified by anodic stripping voltammetry coupled with square wave voltammetry (ASV/SWV) and boron doped diamond (DDB) electrode. An electroanalytical methodology were developed where parameters were optimized for metals determination. Determination of all metals was performed in KCl 1 mol.L-1 solution. Cyclic voltammetry analysis showed both metals oxidation and reduction peaks with quasi-reversible characteristic. Parameters of the ASV were equal for all metals except the deposition potential (Edep) that were for cooper -0,2 V ; -1,8 V for zinc and - 0,1 V iron. The deposition time and equilibration time was 180 s and 60 s respectively. Regarding SWV parameters, it was diverse for each metal, for cooper frequency (f) and amplitude (a) values were 60 Hz and 70mV, for zinc 70 Hz and 80 mV, for iron 70 Hz and 90 mV, respectively. After parameters optimization analytical curves were constructed for each metal and calculated the detection limits which resulted in 0,005; 0,12 and 0,16 ppm for cooper, zinc and iron respectively. The methodology developed for detection of these metals was applied in water samples taken from the Igarapé do Quarenta located in industrial district of Manaus, the analysis showed good repeatability and low error when compared with results obtained by atomic absorption spectroscopy.eng
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico-
dc.formatapplication/pdfpor
dc.thumbnail.urlhttp://200.129.163.131:8080//retrieve/8515/Lidiane.pdf.jpg*
dc.languageporpor
dc.publisherUniversidade Federal do Amazonaspor
dc.publisher.departmentInstituto de Ciências Exataspor
dc.publisher.countryBRpor
dc.publisher.initialsUFAMpor
dc.publisher.programPrograma de Pós-graduação em Químicapor
dc.rightsAcesso Abertopor
dc.subjectCobrepor
dc.subjectZincopor
dc.subjectFerropor
dc.subjectDDBpor
dc.subjectCoppereng
dc.subjectZinceng
dc.subjectIroneng
dc.subjectDDB.eng
dc.subject.cnpqCIÊNCIAS EXATAS E DA TERRA: QUÍMICApor
dc.titleDesenvolvimento de metodologia eletroanalítica para determinação de Cu, Fe e Zn em água empregando eletrodo de diamante dopado com boropor
dc.typeDissertaçãopor
Appears in Collections:Mestrado em Química

Files in This Item:
File Description SizeFormat 
Lidiane.pdf2.47 MBAdobe PDFThumbnail

Download/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.