???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: https://tede.ufam.edu.br/handle/tede/3322
Full metadata record
DC FieldValueLanguage
dc.creatorMota, Fábio Alexandre Costa-
dc.creator.Latteshttp://lattes.cnpq.br/2207667092752016por
dc.contributor.advisor1Santana, Genilson Pereira-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3304605845319238por
dc.date.available2015-04-10-
dc.date.issued2010-02-26-
dc.identifier.citationMOTA, Fábio Alexandre Costa. Desenvolvimento de um fotômetro com fins didáticos. 2010. 83 f. Dissertação (Mestrado em Química) - Universidade Federal do Amazonas, Manaus, 2010.por
dc.identifier.urihttp://tede.ufam.edu.br/handle/tede/3322-
dc.description.resumoFoi desenvolvido um fotômetro para fins didáticos para uso na contextualização de temas químicos sociais, como química ambiental, e em aulas de instrumentação analítica, com determinação de ortofosfato total em águas. Para sua construção foram usados materiais de baixo custo e de fácil aquisição. O aparelho consiste basicamente de um LED (Diodo Emissor de Luz) amarelo como fonte e LDR (Resistor Dependente de Luz) como detector. O sinal do fotômetro é dado em valores de resistividade, medida com uso de multímetro digital. Para a determinação do ortofosfato foi usado o método do azul de molibdênio, sendo águas de um igarapé poluído usados como amostras teste. Para procedimentos de validação analítica, foram feitos testes para configuração mais adequada, optando-se por cubeta de acrílico, escala de 200kW de resistividade e uso de cobertura no aparelho, assim como verificação da estabilidade da fonte. O aparelho foi validado usando critérios de precisão, exatidão, recuperação e linearidade. A precisão intermediária e repetibilidade apresentaram coeficientes de variação médios de 3,0 e 2,8, respectivamente. A exatidão do fotômetro foi verificada com comparação estatística baseadas nos testes F e t para p < 0,05, sendo as mesmas medidas feitas no fotômetro e espectrofotômetro UV-Vis, para fins de comparação. Com 95% de nível de confiança foi revelado que há diferenças significativas entre os valores de concentração, sendo que os resultados foram considerados satisfatórios com o uso de um fator de correção. Os testes de recuperação foram satisfatórios com variações entre 97,6 e 107,3%. A linearidade foi considerada satisfatória no intervalo de 8 a 48 μmol l-1, apresentando valores de r2 acima de 0,99.por
dc.description.abstractIn this work was developed a photometer for didactic purposes for use in the context of social themes chemicals, such as environmental chemistry and classes of analytical instrumentation, with total determination of total orthophosphate in water. The instrument was developed using cheap materials and easy disposal. The instrument consists of a yellow LED and LDR; the first is the source and the former the detector. The signal of the photometer is available by values in resistivity, within is measured with assistance of the digital multimeter. For the determination of the orthophosphate was used the Molybdenum Blue Colorimetric Method, using river waters as test samples. Procedures for analytical validation tests were for the most suitable configuration, choosing a bucket acrylic, range from 200 kW resistivity and use of cover to the apparatus, as well as checking the stability of the source. Accuracy, precision, recovery and linearity of the photometer were checked. The repeatability and intermediate precision had coefficients of variation average 3.0 and 2.8, respectively. Accuracy was examined with statistical comparison based upon test F and t for p < 0.05, with same measures evaluated in the photometer and spectrophotometer UV-Vis, for comparison. With 95% confidence level was revealed that there are significant differences between the values of concentration, and the results were satisfactory with the use of a correction factor The recovery tests were satisfactory, with variations between 97.6 and 107.3%. The linearity is satisfactory in the range 8-48 μmol l-1, with r2 values above 0.99.eng
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado do Amazonas-
dc.formatapplication/pdfpor
dc.languageporpor
dc.publisherUniversidade Federal do Amazonaspor
dc.publisher.departmentInstituto de Ciências Exataspor
dc.publisher.countryBRpor
dc.publisher.initialsUFAMpor
dc.publisher.programPrograma de Pós-graduação em Químicapor
dc.rightsAcesso Abertopor
dc.subjectFerramenta didáticapor
dc.subjectFotômetropor
dc.subjectInstrumentação analíticapor
dc.subjectTeaching tooleng
dc.subjectPhotometereng
dc.subjectAnalytical instrumentationeng
dc.subject.cnpqCIÊNCIAS EXATAS E DA TERRA: QUÍMICApor
dc.titleDesenvolvimento de um fotômetro com fins didáticospor
dc.typeDissertaçãopor
Appears in Collections:Mestrado em Química

Files in This Item:
File SizeFormat 
Dissertacao - Fabio Mota.pdf3.01 MBAdobe PDFDownload/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.