???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: https://tede.ufam.edu.br/handle/tede/4062
???metadata.dc.type???: Dissertação
Title: Estudo sobre o transporte apical e capacidade de limpeza de sistema de instrumento único associado a diferentes técnicas de cateterismo
???metadata.dc.creator???: Carvalho, Guilherme Moreira de 
???metadata.dc.contributor.advisor1???: Marques, André Augusto Franco
???metadata.dc.description.resumo???: O objetivo do presente estudo foi avaliar o trasnporte apical e a capacidade de limpeza promovida por diferentes técnicas de cateterismo associadas ao uso de um sistema de instrumento único. Foram selecionados 52 molares inferiores com grau de curvatura da raiz mesial entre 20° e 40° e raio de curvatura menor ou igual a10 mm. Com o auxílio de instrumentos tipo K #10, avaliou-se a presença de forames independentes. Com o objetido de padronizar o tamanho dos dentes, as coroas foram parcialmente seccionadas em 16 mm e mediu-se 3 milímetros na raiz mesial, que foram transpostos para a raiz distal, e esta foi seccionada naquele ponto. Os dentes selecionados foram separados aleatoriamente (n=13) dentes cada, Grupo 1, cateterismo inicial com lima manual tamanhos 10 e 15 e instrumentação com R25; Grupo 2, Reciproc R25 sem cateterismo; Grupo 3, cateterismo com PathFile e preparo com Reciproc R25 e Grupo 4, controle, que não foi instrumentado. Em seguida, a raiz distal foi inserida em blocos de resina, para padronização das tomografias na mesma posição antes e após a instrumentação e para ser afixado em uma morsa de bancada, a fim de se padronizar a posição de instrumentação. O comprimento de trabalho dos canais mesiais foi definido a 0,5 mm aquém ao ápice. Após o cateterismo, os canais foram instrumentados seguindo as recomendações do fabricante. Hipoclorito de sódio a 2,5% foi a solução irrigadora utilizada. Após a instrumentação, os dentes foram submetidos novamente a tomografia e em seguida o terço apical de cada espécime foi submetido ao processamento histotécnico de rotina para obtenção de 12 cortes com 5 μm de espessura. A análise do desvio apical se deu pela aplicação de fórmulas aos valores obtidos antes e após a instrumentação e a análise histológica se deu pela avaliação dos cortes histológicos e determinação do percentual de debris presente nos canais por meio da sobreposição de uma grade de integração. Os dados obtidos foram submetidos a testes de Kruskall-Wallis e teste de Múltiplas Comparações de Dunn. Os resultados do desvio apical não mostraram diferenças significantes entre os grupos avaliados (p > 0,05). Em relação a capacidade de limpeza, houve diferença significativa entre o grupo 1 e o grupo 2 (p ˂ 0,01). Com base na metodologia empregada e nos resultados obtidos, concluiu-se que não houve diferença significante em relação ao desvio apical entre as diferentes técnicas de cateterismo, o sistema Reciproc, sem cateterismo prévio, apresentou maior capacidade de limpeza do sistema de canais radiculares.
Abstract: The purpose of this study was to evaluate apical transportation using CT Scans, and, using histological analysis, to evaluate the cleaning effectiveness of different glide path techniques associated with the use of Reciproc system`s R25 instrument. To perform the experiment, 52 mandibular molars were selected, with mesial root canal curvature between 20° and 40° and canal curvature radius less than or equal to 10 mm. Size 10 K-type instruments were used to determine the presence of independent foramen. In order to standardize tooth size, the crowns were partially sectioned at 16 mm and then measured 3 mm in the mesial root, which were transferred to the distal root, to be sectioned at that point. The selected teeth were divided into four groups of 13: Group 1: glide path with manual file, sizes 10 and 15 and instrumentation with the R25; Group 2: Reciproc R25 without a glide path; Group 3: the glide path performed with PathFile and instrumentation with the Reciproc R25 and Group 4: control group, no instrumentation. The distal root was then embedded in resin blocks for the scans to be standardized in the same position, before and after instrumentation, and to be fixed in a vise, in order to standardize instrumentation position. The working length of the mesial canals was set at 0.5 mm from the apex. After performing the glide path, the root canals were prepared following manufacturer recommendations. Sodium hypochlorite 2.5% was the irrigating solution used. After instrumentation, teeth again underwent CT scanning, after which the apical third of each specimen was subjected to routine histotechnical processing in order to obtain 12 sections 5 μm thick. Apical deviation was assessed by applying formulas to values obtained before and after instrumentation and histological analysis was performed by evaluating the histological sections with a 230x magnification and the quantification of debris through the superposition of a grid. Data were subjected to the Kruskal-Wallis Test and the Dunn Multiple Comparisons Test. The results of the apical deviation presented no significant difference between the experimental groups (p > 0,05). As for cleaning ability, the difference between groups 1 and 2 was found to be statistically significant (p ˂ 0,01). The methodology and the results lead to the conclusion that the glide path technique used did not produce a statistically significant difference in apical deviation. However, the Reciproc system instrumentation technique, without a glide path, showed greater capacity for cleaning the root canal system.
Keywords: Instrumentação
Endodontia
Preparo de Canal Radicular
Desvio Apical
Instrumentation
Root Canal Preparation
Apical Deviation
???metadata.dc.subject.cnpq???: CIÊNCIAS DA SAÚDE: ODONTOLOGIA
Language: por
???metadata.dc.publisher.country???: Brasil
Publisher: Universidade Federal do Amazonas
???metadata.dc.publisher.initials???: UFAM
???metadata.dc.publisher.department???: Faculdade de Odontologia
???metadata.dc.publisher.program???: Programa de Pós-graduação em Odontologia
Citation: CARVALHO, Guilherme Moreira de. Estudo sobre o transporte apical e capacidade de limpeza de sistema de instrumento único associado a diferentes técnicas de cateterismo. 2015. 122 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Amazonas, Manaus, 2015.
???metadata.dc.rights???: Acesso Aberto
URI: http://tede.ufam.edu.br/handle/tede/4062
Issue Date: 20-Apr-2015
Appears in Collections:Mestrado em Odontologia

Files in This Item:
File Description SizeFormat 
Dissertação - Guilherme Moreira de Carvalho.pdfDissertação - Guilherme Moreira de Carvalho2.34 MBAdobe PDFThumbnail

Download/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.