???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: https://tede.ufam.edu.br/handle/tede/4976
???metadata.dc.type???: Dissertação
Title: A influência do aquecimento na estrutura semicristalina da Polianilina Sal de Esmeraldina (PANI-ES)
???metadata.dc.creator???: Oliveira, Lilian Rodrigues 
???metadata.dc.contributor.advisor1???: Sanches, Edgar Aparecido
???metadata.dc.description.resumo???: A polianilina (PANI) é um polímero intrinsecamente condutor (PIC) que é muito estudado em diversas pesquisas devido as suas aplicações tecnológicas. O intuito desta pesquisa é investigar as modificações ocorridas na estrutura, morfologia e condutividade elétrica da Polianilina Sal de Esmeraldina (PANI-ES), quando a mesma é submetida a tratamento térmico nas temperaturas de 50, 100, 200 e 300°C, com duração de 1h para cada temperatura. A PANI-ES foi sintetizada quimicamente com Persulfato de Amônio e HCl 1M e as amostras foram caracterizadas utilizando-se as técnicas de DRX, SAXS, FTIR e MEV. Através dos dados obtidos por DRX, verificou-se a perda de cristalinidade das amostras tratadas termicamente através da modificação dos perfis dos difratogramas. Os dados de DRX também foram utilizados para realização do ajuste Le Bail visando à obtenção de informações microestruturais através do programa FULLPROF e para a estimativa do percentual de cristalinidade utilizando o programa Peak Fitting Module. No ajuste Le Bail foram adquiridos os valores dos tamanhos médios e anisotrópicos dos cristalitos: para a PANI-ES foi encontrado o valor de 36 Å e para as amostras tratadas termicamente, TT (50), TT (100), TT (200) e TT (300), este valor foi gradativamente diminuindo até chegar a 16 Å em 300 °C. Os percentuais de cristalinidade obtidos para PANI-ES e as amostras tratadas termicamente variaram de 51 para 19%. Através do SAXS foram obtidos os valores dos raios de giro (𝑅𝑔) e a dimensão máxima das partículas (𝐷𝑚á𝑥 ) a partir da função de distribuição de pares p(r). Os dados de SAXS também foram utilizados para reconstrução estrutural do modelo do formato das partículas, mostrando que a temperatura ocasionou a perda do formato globular das partículas, bem como suas dimensões máximas e raios de giro foram diminuídos com o tratamento térmico. As análises de FTIR revelam que, quando a PANI-ES é submetida a 200°C ocorre uma mudança estrutural na cadeia polimérica através da reação de crosslinking, porém, sem ganho de cristalinidade. As imagens de MEV permitiram a visualização das distintas morfologias das amostras: a PANI-ES apresentou uma morfologia de nanofibras formadas por nanoesferas interconectadas, enquanto que as amostras tratadas termicamente perderam essa morfologia inicial, apresentando nanofibras muito menores e menos definidas, refletindo na perda de cristalinidade e condutividade elétrica das amostras. As medidas de condutividade elétrica foram diminuindo em virtude do tratamento térmico: a PANI-ES apresentou condutividade elétrica da ordem de 0,3 x 10-4 S/cm e, após o tratamento térmico, a condutividade elétrica chegou a 4 x 10-6 S/cm, representando uma diminuição de 86%. Assim, esta pesquisa permitiu, através da caracterização estrutural e morfológica da PANI-ES, investigar as alterações ocorridas em sua estrutura após o tratamento térmico, e constatar que a diminuição do percentual de cristalinidade influencia nos valores de condutividade elétrica. Espera-se que estes resultados possam contribuir para um maior conhecimento das propriedades estruturais, morfológicas e elétricas dos materiais poliméricos
Abstract: Polyaniline (PANI) is an Intrinsically Conducting Polymer (ICP) which is very studied in several areas due to their technological applications. The purpose of this study is to investigate the changes occurring in the structure, morphology and electrical conductivity of Polyaniline Esmeraldine Salt form (PANI-ES) when it is subjected to heat treatment at temperatures of 50, 100, 200 and 300 °C for 1h at each temperature. PANI-ES was chemically synthesized with ammonium persulfate and HCl 1M, and the samples were characterized using XRD, SAXS, FTIR and SEM techniques. By XRD a loss of crystallinity was observed after heating treatment. XRD data were also used to perform the Le Bail method in order to obtain microstructural information through FullProf program and to estimate the percentage of crystallinity using the Peak Fitting Module program. Through Le Bail method the values of average and anisotropic crystallite sizes were acquired: for PANI-ES it was found the value of 36 Å and for the heat treated samples, TT (50) TT (100), TT (200) and TT (300), these values were gradually narrowed until it reaches 16 Å at 300 °C. The percentage of crystallinity obtained for the PANI-ES and heat-treated samples ranged from 51 to 19%. Through the SAXS technique it were obtained the values of the radius of gyration (Rg), and the maximum particle size (Dmáx) from the pair distribution function p(r). The SAXS data were also used for structural reconstruction of the model for particle size, showing that the increasing of temperatures caused a significant loss of globular particle shape and their maximum particle size (Dmáx) and radius of gyration (Rg) were decreased after the heat treatment. FTIR analyzes showed a crosslinking reaction when PANI-ES was subjected to 200 °C, with no gain of crystallinity. SEM technique allowed different morphologies visualization: PANI-ES showed a nanofiber morphology formed by interconnected nanospheres, while samples heat treated lost this initial morphology having much smaller and less defined nanofibers, reflecting the loss of electrical conductivity and crystallinity. The electrical conductivity measurements have been decreasing because of the heat treatment: PANI-ES showed electrical conductivity of 0.3 x 10-4 S/cm and, after the heat treatment, the electric conductivity reached 4 x 10-6 S/cm, representing a decrease of 86%. Thus, this research allowed the structural and morphological characterization of PANI-ES, investigating the changes in its structure after heat treatment, and found that the decrease in the percentage of crystallinity influences in their electrical conductivity values. It is hoped that these results will contribute to a better understanding of the structural, morphological and electrical properties of polymeric materials
Keywords: Polianilina
Polyaniline
Difração de Raios X
Microscopia Eletrônica de Varredura (MEV)
???metadata.dc.subject.cnpq???: CIÊNCIAS EXATAS E DA TERRA: FÍSICA
Language: por
???metadata.dc.publisher.country???: Brasil
Publisher: Universidade Federal do Amazonas
???metadata.dc.publisher.initials???: UFAM
???metadata.dc.publisher.department???: Instituto de Ciências Exatas
???metadata.dc.publisher.program???: Programa de Pós-graduação em Física
Citation: OLIVEIRA, Lilian Rodrigues de. A influência do aquecimento na estrutura semicristalina da Polianilina Sal de Esmeraldina (PANI-ES). 2015. 80f. Dissertação (Mestrado em Física) - Universidade Federal do Amazonas, Manaus, 2015.
???metadata.dc.rights???: Acesso Aberto
URI: http://tede.ufam.edu.br/handle/tede/4976
Issue Date: 19-Oct-2015
Appears in Collections:Mestrado em Física

Files in This Item:
File Description SizeFormat 
Dissertação - Lilian Rodrigues.pdfReprodução Total Autorizada3.98 MBAdobe PDFThumbnail

Download/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.