???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: https://tede.ufam.edu.br/handle/tede/5429
???metadata.dc.type???: Dissertação
Title: Avaliação de protocolo usando ultrassom na remoção de retentores metálicos em dentes multirradiculares
???metadata.dc.creator???: Graça, Izabela Araújo Aguiar 
???metadata.dc.contributor.advisor1???: Garrido, Angela Delfina Bittencourt
???metadata.dc.description.resumo???: Entre as técnicas empregadas para a remoção dos retentores, a vibração ultrassônica tem sido a mais eficiente. Há uma escassez de estudos de técnicas para remoção de retentores metálicos em dentes multirradiculares. Este trabalho avaliou in vitro um protocolo de remoção que consiste na confecção de um túnel na porção coronária do retentor e aplicação de ultrassom nessa cavidade. Quarenta molares inferiores foram tratados endodonticamente usando sistema de lima única com movimento reciprocante e obturados utilizando a técnica de termocompactação, recebendo retentores intrarradiculares fundidos e sendo alocados em 4 grupos de acordo com o protocolo de remoção: GRUPO I – sem túnel e sem vibração ultrassônica, GRUPO II – sem túnel e com vibração ultrassônica na porção coronária do núcleo, GRUPO III – com túnel e sem vibração ultrassônica e GRUPO IV – com túnel e com vibração ultrassônica no interior do túnel. O teste de tração foi realizado em todas as amostras na Máquina Universal de Ensaio EMIC DL-2000 com velocidade de 1 mm/min obtendo valores em Newton e os dados foram submetidos à análise estatística ANOVA e Tukey- Kramer (p <0.05). Os resultados mostraram diferenças estatisticamente significantes entre os grupos testados (GI - 322,74 N; GII - 283.09 N; GIII - 244,00 N; GIV - 237,69 N).A menor média de força foi encontrada no grupo que ocorreu a vibração ultrassônica no interior do túnel. Os resultados demonstraram que a confecção do túnel no núcleo e vibração ultrassônica no interior dele reduz a força de tração necessária para a remoção. Este protocolo de remoção se mostrou efetivo para remoção de retentores em dentes multirradiculares fixados com fosfato de zinco.
Abstract: Among the techniques employed for the removal of the retainers, the ultrasonic vibration has been the most efficient. There is a lack of studies techniques for removing metal retainers in multirooted teeth. This study evaluated in vitro a removal protocol consisting of making a tunnel in the coronal portion of the retainer and application of ultrasound in this cavity. Forty molars were endodontically treated using single file system with reciprocating movement and filled using thermoplasticized technique, receiving cast intraradicular retainers and being allocated into 4 groups according to the removal protocol: GROUP I - no tunnel and no ultrasonic vibration, GROUP II - without tunnel and ultrasonic vibration in the coronal portion of the core, GROUP III - with tunnel and without ultrasonic vibration and GROUP IV - with tunnel and ultrasonic vibration inside the tunnel. The tensile test was performed on all samples in the EMIC DL-2000 universal testing machine with a speed of 1 mm / min values obtained in Newton and the data were statistically analyzed using ANOVA and Tukey- Kramer (p <0.05). The results showed statistically significant differences between the groups tested (GI - 322.74 N; GII - 283.09 N; GIII - 244.00 N; GIV - 237.69 N). The lowest average power was found in the group that was the ultrasonic vibration inside the tunnel.The results demonstrated that preparing the tunnel in the core and ultrasonic vibration within it reduces the force required for removing. This removal protocol was effective for removal intraradicular metal retainers multirooted teeth cemented with zinc phosphate.
Keywords: Retentores intrarradiculares
Força de tração
Dentes multirradiculares
???metadata.dc.subject.cnpq???: CIÊNCIAS DA SAÚDE: ODONTOLOGIA
Language: por
???metadata.dc.publisher.country???: Brasil
Publisher: Universidade Federal do Amazonas
???metadata.dc.publisher.initials???: UFAM
???metadata.dc.publisher.department???: Faculdade de Odontologia
???metadata.dc.publisher.program???: Programa de Pós-graduação em Odontologia
Citation: GRAÇA, Izabela Araújo Aguiar. Avaliação de protocolo usando ultrassom na remoção de retentores metálicos em dentes multirradiculares. 2016. 42 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Amazonas, Manaus, 2016.
???metadata.dc.rights???: Acesso Aberto
URI: http://tede.ufam.edu.br/handle/tede/5429
Issue Date: 29-Sep-2016
Appears in Collections:Mestrado em Odontologia

Files in This Item:
File Description SizeFormat 
Dissertação - Izabela A. A. Graça.pdf977.4 kBAdobe PDFThumbnail

Download/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.