???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: https://tede.ufam.edu.br/handle/tede/5609
Full metadata record
DC FieldValueLanguage
dc.creatorRomero, Francisco Perdigón-
dc.creator.Latteshttp://lattes.cnpq.br/9255597494613508por
dc.contributor.advisor1Evangelista Neto, João-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/4152416345697810por
dc.contributor.advisor-co1Costa, Marly Guimarães Fernandes-
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/7169358412541736por
dc.contributor.referee1Costa Filho , Cícero Ferreira Fernandes-
dc.contributor.referee2Barbosa, Paulo Roberto Benchimol-
dc.date.issued2016-12-20-
dc.identifier.citationROMERO, Francisco Perdigón. Métodos para a eliminação de flutuações de linha base em sinais de eletrocardiograma: estudo comparativo. 2016. 150 f. Dissertação (Mestrado em Engenharia Elétrica) - Universidade Federal do Amazonas, Manaus, 2016.por
dc.identifier.urihttp://tede.ufam.edu.br/handle/tede/5609-
dc.description.resumoAs doenças cardiovasculares representam a principal causa de morte em nível mundial, sendo responsáveis por 17,3 milhões de mortes por ano. O eletrocardiograma (ECG) é uma técnica não invasiva utilizada amplamente para a detecção de algumas doenças cardiovasculares. Para aumentar a sensibilidade diagnóstica, o ECG é adquirido em ambulatório ou durante provas de esforço físico. Nessas condições de aquisição é afetado fortemente por vários tipos de ruídos, principalmente pelas flutuações de linha base (FLB). Apesar de existirem vários métodos para a eliminação das FLB, não foi identificado nenhum estudo comparativo que avalie quantitativamente estes métodos usando os mesmos sinais. Neste trabalho foi feita uma caraterização espectral das FLB onde foi comprovado que estas contem componentes espectrais em até 3,14 Hz. Tal valor, entretanto, ultrapassa os valores estabelecidos pela American Heart Association. Adicionalmente, foram implementados nove métodos para a eliminação de FLB os quais são: interpolação usando splines cúbicos, filtragem FIR, filtragem IIR, filtragem adaptativa LMS, filtragem de média móvel, análise de componentes independentes, interpolação e subtração de mediana sucessivas, decomposição em modos empíricos e filtragem wavelet. As técnicas implementadas foram avaliadas de forma qualitativa e quantitativa. Para a avaliação quantitativa foram usadas as seguintes métricas de similaridade: distância máxima absoluta, somatória do quadrado das distâncias e porcentagem da distância do erro médio quadrático. Foram realizados vários experimentos utilizando sinais de ECG sintéticos, ECG reais da QT Database, ruídos artificiais e ruídos reais da Noise Strees Test Database. Os melhores resultados foram obtidos com filtragem FIR passa-altas, com frequência de corte de 0,67 Hz.por
dc.description.abstractCardiovascular diseases are the leading cause of death worldwide, accounting for 17.3 million deaths per year. The electrocardiogram (ECG) is a non-invasive technique widely used for the detection of cardiac diseases. To increase diagnostic sensitivity, ECG is acquired during exercise stress tests or in ambulatory way. Under these acquisition conditions the ECG is strongly affected by some types of noise, mainly by baseline (BL) wander. Currently in the literature, there are several methods for the elimination of BL, but no comparative study has been found that quantitatively evaluates these methods using the same signals. In this work a spectral characterization of the BL was made where it has been proven that these contain spectral components up to 3.14 Hz which exceeds the values established by the American Heart Association. We also implemented nine methods for the elimination of BL, which are interpolation using cubic splines, FIR filtering, IIR filtering, LMS adaptive filtering, moving average filter, independent component analysis, interpolation and successive median subtractions, decomposition in empirical modes and wavelet filtering. They were evaluated qualitatively and quantitatively. For the quantitative evaluation, the following similarity metrics were used: absolute maximum distance, sum of squares of distances and percentage of mean square error distance. Several experiments were performed using synthetic ECG signals, real QT Database ECG, artificial and real BL noises from the Noise Stress Test Database. The best results were obtained by the method based on FIR high pass filtering with cutoff frequency of 0.67 Hz.eng
dc.description.sponsorshipCAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superiorpor
dc.formatapplication/pdf*
dc.thumbnail.urlhttp://tede.ufam.edu.br//retrieve/16021/Disserta%c3%a7%c3%a3o%20-%20Francisco%20P.%20Romero.pdf.jpg*
dc.languageporpor
dc.publisherUniversidade Federal do Amazonaspor
dc.publisher.departmentFaculdade de Tecnologiapor
dc.publisher.countryBrasilpor
dc.publisher.initialsUFAMpor
dc.publisher.programPrograma de Pós-graduação em Engenharia Elétricapor
dc.rightsAcesso Abertopor
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectFlutuações de linha basepor
dc.subjectECG - Modelagem dos eletrodospor
dc.subjectECG - Ruído eletrocirúrgicopor
dc.subjectEletrocardiograma (ECG)por
dc.subject.cnpqENGENHARIAS: ENGENHARIA ELÉTRICApor
dc.titleMétodos para a eliminação de flutuações de linha base em sinais de eletrocardiograma: estudo comparativopor
dc.typeDissertaçãopor
Appears in Collections:Mestrado em Engenharia Elétrica

Files in This Item:
File Description SizeFormat 
Dissertação - Francisco P. Romero.pdf7.45 MBAdobe PDFThumbnail

Download/Open Preview


This item is licensed under a Creative Commons License Creative Commons