Title: Estudo de dosagem de concreto permeável para pavimento leve incorporando metacaulinita como substituto parcial do cimento
???metadata.dc.creator???: Araújo, Jociane da Silva 
???metadata.dc.contributor.advisor1???: Campelo, Nilton de Souza
???metadata.dc.contributor.referee1???: Rocha, Francisco dos Santos
???metadata.dc.contributor.referee2???: Ribas, Luciane Farias
???metadata.dc.description.resumo???: A impermeabilização dos solos urbanos afeta diretamente o aumento do escoamento superficial e infiltração dos solos. O concreto permeável usado em pavimentos apresenta-se como uma ação mitigadora para essas questões. A ausência total de finos ou a redução da maior parte dele caracteriza a alta permeabilidade e baixa resistência desse concreto. Na pesquisa é introduzida a metacaulinita no concreto permeável para substituição parcial do cimento. O estudo foi realizado com ensaios laboratoriais para verificação de resistências mecânicas e determinação da taxa de infiltração da água. As misturas utilizadas neste estudo consistiram em dois tamanhos agregados e dois tipos de agregados graúdos. Os ensaios foram realizados em amostras de referência nas quais não havia substituição do cimento. Como o trabalho foi desenvolvido para placas de concreto de permeável a NBR 16416 (ABNT, 2015) determina que a resistência a tração na flexão alcance o mínimo 2 MPa. Dessa forma foi estabelecido que as amostras de referência deveriam alcançar um mínimo de resistência de compressão 8 MPa. Esse resultado foi atingindo após o ajuste das dosagens e o incremento de 5% de areia. Após atingir o objetivo foi realizada a substituição de 15% do cimento por metacaulinita. As características mecânicas de compressão depois da substituição atingiram resistência à compressão simples de aproximadamente 10 MPa e de resistência à tração na flexão ficou com aproximadamente 2,1 MPa. A taxa de infiltração da água ficou com valores em torno de 0,14cm/s. O estudo permitiu avaliar que o seixo e a brita 0 não apresentaram diferenças significativas quanto a resistências mecânicas e permeabilidade. A substituição do cimento por metacaulinita aumentou o consumo de água o que provavelmente está ligado a maior área especifica desse material. A metacaulinita é um material fino e como umas das características do concreto permeável é a ausência total o quase total do materiais finos a sua aplicação não diminuiu de forma expressiva a permeabilidade do concreto.
Abstract: The waterproofing of urban soils directly affects the increase of surface runoff and soil infiltration. The permeable concrete used in pavements presents itself as a mitigating action for these issues. The total absence of fines or the reduction of most of them characterizes the high permeability and low strength of this concrete. In research, metakaolinite is introduced in permeable concrete to partially replace cement. The study was carried out with laboratory tests to check mechanical strength and determine the rate of water infiltration. The mixtures used in this study consisted of two aggregate sizes and two types of coarse aggregates. The tests were performed on reference samples in which there was no replacement of cement. As the work was developed for concrete slabs of permeable, NBR 16416 (ABNT, 2015) determines that the flexural tensile strength reaches the minimum 2 MPa. Thus, it was established that the reference samples should reach a minimum compression strength of 8 MPa. This result was achieved after adjusting the dosages and increasing the sand by 5%. After reaching the goal, 15% of cement was replaced by metakaolinite. The mechanical compression characteristics after the replacement reached a simple compressive strength of approximately 10 MPa and a tensile strength in flexion was approximately 2.1 MPa. The water permeation rate was at values around 0,14cm / s. The study allowed to evaluate that the pebble and the gravel 0 did not present significant differences regarding the mechanical resistance and permeability. The substitution of cement with metakaolinite increased water consumption, which is probably linked to a larger specific area of this material. Metakaolin is a fine material and as one of the characteristics of permeable concrete is the total absence of almost fine materials, its application has not significantly reduced the permeability of concrete.
Keywords: Pavimentos de concreto
Concreto - Testes
Concreto - Mistura
???metadata.dc.subject.cnpq???: ENGENHARIAS: ENGENHARIA CIVIL: CONSTRUÇÃO CIVIL: MATERIAIS E COMPONENTES DE CONSTRUÇÃO
???metadata.dc.subject.user???: Dosagem
Concreto permeável
Pavimento
Metacaulinita
Language: por
???metadata.dc.publisher.country???: Brasil
Publisher: Universidade Federal do Amazonas
???metadata.dc.publisher.initials???: UFAM
???metadata.dc.publisher.department???: Faculdade de Tecnologia
???metadata.dc.publisher.program???: Programa de Pós-graduação em Engenharia Civil
Citation: ARAUJO, Jociane da Silva. Estudo de dosagem de concreto permeável para pavimento leve incorporando metacaulinita como substituto parcial do cimento. 2019. 84 f. Dissertação (Mestrado em Engenharia Civil) - Universidade Federal do Amazonas, Manaus (AM), 2019.
???metadata.dc.rights???: Acesso Aberto
???metadata.dc.rights.uri???: http://creativecommons.org/licenses/by-nd/4.0/
URI: https://tede.ufam.edu.br/handle/tede/8002
Issue Date: 12-Dec-2019
Appears in Collections:Mestrado em Engenharia Civil

Files in This Item:
File Description SizeFormat 
Dissertação_JocianeAraujo_PPGEC.pdf3.63 MBAdobe PDFThumbnail

Download/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.