???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: https://tede.ufam.edu.br/handle/tede/2229
???metadata.dc.type???: Dissertação
Title: Desenvolvimento de imunossensor para detecção de fator de necrose tumoral (TNF-ALFA)
???metadata.dc.creator???: Lima, Michella Bezerra 
???metadata.dc.contributor.advisor1???: Santos, Maria Cristina dos
???metadata.dc.description.resumo???: Os imunossensores, ou biossensores de imunoafinidade são sistemas que exploram a seletividade e especificidade das interações antígeno-anticorpo, para detecção do analito alvo. O objetivo deste trabalho foi o desenvolvimento de um imunossensor, em que anticorpos monoclonais (anti-TNF-α humano) foram imobilizados em superfícies modificadas de ouro, para reconhecimento específico do Fator de Necrose Tumoral Alfa humano (TNF-α). Para a imobilização dessas imunoglobulinas foi necessária a formação de uma monocamada auto-organizada (SAM) sobre a superfície do sensor, composta por 3-aminopropiltrietóxisilano (APTS), sendo testadas quatro concentrações diferentes (1%, 2,5%, 5% e 10%), em dois tipos de solventes, água deionizada e tolueno, para comparação de metodologias para obtenção de melhores respostas. Os métodos de caracterização adotados foram a espectroscopia de Ressonância de Plásmon de Superfície (SPR), para análise da imobilização de anticorpos, na superfície modificada do sensor e a resposta dos sistemas desenvolvidos para detecção do TNF-α; e, Microscopia de Força Atômica (AFM), para verificação topográfica da SAM da superfície sensora. Os resultados mostraram que as melhores condições de desenvolvimento do biossensor desenvolvido neste trabalho ocorreram com a utilização de APTS 2,5% em tolueno, bloqueado com BSA 1%. O biossensor apresentou 24 pg.mm-2 (198,3  28,4 mgrau) de TNF-α humano imobilizados na superfície de ouro, e após injeções sucessivas de 25 pg.mL-1 de antígeno (n=8), em triplicata experimental, obtivemos uma região linear de resposta de 4,3 a 34.7 pg.mm-2 (R=0.98, SD=2.18, p<0.0001). Em análise topográfica das superfícies sensoras, realizada por AFM, foi observado que as amostras preparadas em tolueno, com melhores respostas de reconhecimento do antígeno, apresentaram menor uniformidade na sua estrutura, em razão da maior rugosidade detectada. Foi desenvolvido um imunossensor experimental, que servirá como modelo para o desenvolvimento de biossensor para aplicação clínica futura para quantificação de TNF- humano em fluidos corporais de pacientes portadores de doenças inflamatórias
Abstract: The development of analytical and low cost methods for fast safe diagnosis and control of illnesses in humans has been one of researchers great interests in the last two decades. This attention is also due to simplicity of use and the great sensitivity in the results. Biosensors based on the surface plasmon resonance (SPR) technique combines the inherent specificity of the recognition elements with high sensitivity of physical transducers, enabling selective and sensitive detection of the analytes of interest without labeling and preliminary purification steps. We proposed the development of a biosensor with immobilized monoclonal antibodies on gold surface, for specific recognition of TNF-α using SPR technique. Design. Anti-TNF-α antibody was covalently immobilized on a gold substrate by silane coupling chemistry. After this, TNF-α antigens aliquots were added on the biosensor surface and the signal was measured during three minutes for TNF-α mass quantification recognized by immobilized antibodies. Results.This biosensor presented 24.0 pg.mm-2 (198,3  28,4) of antibodies immobilized on gold surface. TNF-α human was determined from successive injections, with a linear range from 4.3 up to 34.7 pg/mm-2 (R=0.98, SD=2.18, p<0.0001). Conclusion. We performed a preliminary biosensor to quantify TNF-α for planning of diseases treatment, such as auto immune and periodontal diseases, in which TNF-α inhibitor therapy is usually applied. In this cases, it would be necessary the quantification of this cytokine for therapeutic dose adjustment, improving treatment effectiveness and costs reduction. In the next step we intend to optimize the biosensors conditions preparation as well as to test it in human body fluids samples
Keywords: Biossensor
Imunossensor
Biosensor
Immunosensor
???metadata.dc.subject.cnpq???: CIÊNCIAS BIOLÓGICAS
Language: por
???metadata.dc.publisher.country???: BR
Publisher: Universidade Federal do Amazonas
???metadata.dc.publisher.initials???: UFAM
???metadata.dc.publisher.department???: Instituto de Ciências Biológicas
???metadata.dc.publisher.program???: Programa de Pós-Graduação em Biotecnologia
Citation: LIMA, Michella Bezerra. Desenvolvimento de imunossensor para detecção de fator de necrose tumoral (TNF-ALFA). 2008. 109 f. Dissertação (Mestrado em Biotecnologia) - Universidade Federal do Amazonas, Manaus, 2008.
???metadata.dc.rights???: Acesso Aberto
URI: http://tede.ufam.edu.br/handle/tede/2229
Issue Date: 21-Aug-2008
Appears in Collections:Mestrado em Biotecnologia

Files in This Item:
File Description SizeFormat 
Dissertação_Michella B. Lima.pdf2.84 MBAdobe PDFThumbnail

Download/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.