Title: Levantamento do potencial de eficiência energética no setor de serviços: Sistema de Abastecimento de Água na cidade de Manaus – AM
???metadata.dc.creator???: Jesus, Sandro Simas de 
???metadata.dc.contributor.advisor1???: Cartaxo, Elizabeth Ferreira
First advisor-co: Figueiredo, Carlos Alberto
???metadata.dc.contributor.referee1???: Cartaxo, Elizabeth Ferreira
???metadata.dc.contributor.referee2???: Figueiredo, Carlos Alberto
???metadata.dc.contributor.referee3???: Kuwahara, Nelson
???metadata.dc.description.resumo???: O trabalho efetivou uma coleta de dados e informações sobre as características dos potenciais de eficiência energética no sistema de abastecimento de água, operado pela empresa privada Manaus Ambiental S.A, detentora da concessão do serviço público, na sede do município de Manaus – AM. Para tanto, foi realizado um conjunto de medições dos indicadores de desempenho elétrico nos conjuntos de motores elétricos operados em cinco unidades consumidoras de energia elétrica. As medições elétricas abrangeram 24 h de atividade na rotina operacional das unidades consumidoras, foi observado o limite máximo de tensão operacional de 440 V, não foram aferidos os conjuntos elétricos que operam em 6,6 KV. O estudo identificou ocorrência de fatores de potencia abaixo do padrão estabelecidos pela legislação da ANEEL, ressalta-se que as potências ativas trifásicas demonstraram ocorrência de conjuntos de motores elétricos sobredimensionados. Assim, foi possível estimar potenciais de redução, entre 59,72% e 7,36%, resultando num percentual médio de redução de 25,87% na potência em operação das cinco unidades consumidoras pesquisadas. Em relação aos potenciais associados aos volumes de água produzidos, foram estimados percentuais de perdas de 76,88% a 73,58%, entre a relação de distribuição e faturamento de água. Por fim, ante estas expressivas perdas na rotina operacional da concessionária em 2014, fez-se um contraste entre os percentuais médios de perdas na distribuição de água entre as cinco regiões geográficas do Brasil, com os indicadores do Sistema Nacional de Informações de Saneamento – SNIS, cujos valores médios apresentaram variação regional entre 50,8% e 33,4%, e a perda média nacional de 37,0%. No âmbito desta pesquisa, ficaram evidenciados os níveis de perdas que excedem à média nacional e os potenciais técnicos de redução e a oportunidade de potencial para eficiência energética
Abstract: The work was accomplished a collection of data and information about the characteristics of the potential of energy efficiency in the water supply system, operated by the private company Manaus Ambiental S.A., which holds the concession of public services, in the city of Manaus-AM. To this end, was conducted a set of measurements of the electrical performance indicators in sets of electric motors operated in five consumer units of electricity. The electrical measurements covered 24hours of activity in the operational routine of consumer units, noted the maximum operating voltage of 440 V, were not measured electrical assemblies operating at 6.6 KV. The study identified factors occurrence of substandard potency established by ANEEL's legislation, it should be noted that the three-phase active powers demonstrated occurrence of oversized electric motors. Thus, it was possible to estimate the reduction potential, between 59.72% and 7.36%, resulting in an average percentage of 25.87% reduction in power in operation of the five consumer units surveyed. Relative to the potential associated with the volumes of water produced, were estimated percentages of 76.88% losses to 73.58%, between the distribution and billing of water. Finally, at these significant losses in the operational routine of the concessionaire in 2014, there was a contrast between the average percentage of losses in the distribution of water among the five geographic regions of Brazil, with the indicators of the National Sanitation Information System-SNIS, whose average values showed regional variation between 50.8% and 33.4%, and the national average of 37.0% loss. In the context of this study, loss levels were evidenced that exceed the national average and the technical reduction potential and the potential opportunity for energy efficiency.
Keywords: Energia elétrica
Eficiência energética
???metadata.dc.subject.cnpq???: ENGENHARIAS: ENGENHARIA ELÉTRICA
Language: por
???metadata.dc.publisher.country???: Brasil
Publisher: Universidade Federal do Amazonas
???metadata.dc.publisher.initials???: UFAM
???metadata.dc.publisher.department???: Faculdade de Tecnologia
???metadata.dc.publisher.program???: Programa de Pós-graduação em Engenharia de Recursos da Amazônia
Citation: JESUS, Sandro Simas de. Levantamento do potencial de eficiência energética no setor de serviços: Sistema de Abastecimento de Água na cidade de Manaus – AM. 2015. 102f. Dissertação (Mestrado em Engenharia de Recursos da Amazônia) - Universidade Federal do Amazonas, Manaus, 2015.
???metadata.dc.rights???: Acesso Aberto
URI: http://tede.ufam.edu.br/handle/tede/4839
Issue Date: 2-Oct-2015