???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: https://tede.ufam.edu.br/handle/tede/10011
???metadata.dc.type???: Dissertação
Title: Avaliação de técnicas de fixação interna estável em dois desenhos de osteotomias dos ramos mandibulares: análise de elementos finitos
???metadata.dc.creator???: Silva, Kaline de Moura 
???metadata.dc.contributor.advisor1???: Moura, Andrezza Lauria de
First advisor-co: Jesus, Giorge Pessoa de
???metadata.dc.contributor.referee1???: Batista, Bruno Bellaguarda
???metadata.dc.contributor.referee2???: Byk, Jonas
???metadata.dc.description.resumo???: OBJETIVOS: Avaliar e comparar, por meio da análise tridimensional de elementos finitos, duas técnicas de fixação interna estável em dois desenhos de osteotomia sagital dos ramos mandibulares, bem como confeccionar dois relatórios delineando as técnicas e a repercussão das forças oclusais no pós-operatório. METODOLOGIA: Foi criado modelo tridimensional em elementos finitos de uma hemimandíbula, com desenho de dois tipos de osteotomias sagitais dos ramos mandibulares com avanço ósseo (5mm), simulado por computador. Os modelos foram fixados com duas técnicas de fixação diferentes: uma miniplaca de titânio do sistema Arnett (1mm) para cirurgia ortognática e quatro parafusos monocorticais e uma técnica híbrida (placa fixada com parafusos monocorticais e parafuso bicortical). Foi aplicada uma carga vertical fixa em 200N, aplicada na região da superfície oclusal do primeiro molar inferior e de 100N no superfície incisal do incisivo central. RESULTADOS: Notou-se uma diferença no deslocamento do conjunto, que se desloca de forma muito mais acentuada quando não há um parafuso bicortical. Quanto a distribuição de tensões, o modelo com parafuso bicortical apresentou vantagens em relação ao modelo sem parafuso. Entretanto, percebe-se que o modelo com corte baixo apresenta menores deslocamentos, se comparado ao corte convencional. Para os componentes metálicos, o corte baixo apresenta menores valores de deformação, embora a diferença não seja tão pronunciada. CONCLUSÃO: A técnica híbrida, com o uso de parafusos bicorticais de 2,0 mm, se mostrou mais rígida e registrou valores de tensão mais baixos tanto no osso quanto na placa, menor deformação e deslocamentos em comparação com o uso de somente uma miniplaca de titânio do sistema Arnett (1,0mm) para cirurgia ortognática e quatro parafusos monocorticais para todos os movimentos e forças mandibulares.
Abstract: PURPOSE: To evaluate and compare, using three-dimensional analysis of finite elements, two techniques of stable internal fixation in two drawings of sagittal osteotomy of the mandibular rami, as well as preparing two reports outlining the techniques and the repercussions of occlusal forces in the postoperative period through. METHODS: A three-dimensional finite element model of a hemimandible was created, with the design of two types of sagittal osteotomies of the mandibular rami with two different fixation techniques: a titanium miniplate of the Arnett system (1mm) for orthognathic surgery and four monocortical screws and a hybrid technique (plate fixed with monocortical screws and bicortical screw). A fixed vertical load of 200N was applied to the region of the occlusal surface of the lower first molar and of 100N to the incisal surface of the central incisor. RESULTS: There was a difference in the displacement of the set, which displaces in a much more accentuated way when there is no bicortical over the model without screw. However, it is clear that the model with short cut presents smaller displacements, when compared to the conventional cut. For metallic components, the low cut shows lower strain values, although the difference is not as pronounced. CONCLUSION: The hybrid technique, using 2.0 mm bicortical screws, proved to be more rigid and registered lower stress values both in the bone and in the plate, less deformation and displacements in comparison with the use of only a titanium miniplate of Arnett system (1.0mm) for orthognathic surgery and four monocortical screws for all mandibular movements and forces.
Keywords: Cirurgia bucal
Cirurgia ortognática
Análise de elementos finitos
???metadata.dc.subject.cnpq???: CIENCIAS DA SAUDE
???metadata.dc.subject.user???: Cirurgia ortognática
Análise de elementos finitos
Cirurgia
Language: por
???metadata.dc.publisher.country???: Brasil
Publisher: Universidade Federal do Amazonas
???metadata.dc.publisher.initials???: UFAM
???metadata.dc.publisher.department???: Faculdade de Medicina
???metadata.dc.publisher.program???: Programa de Pós-graduação em Cirurgia
Citation: SILVA, Kaline de Moura. Avaliação de técnicas de fixação interna estável em dois desenhos de osteotomias dos ramos mandibulares: análise de elementos finitos. 2023. 181 f. Dissertação (Mestrado em Cirurgia) - Universidade Federal do Amazonas, Manaus, 2023.
???metadata.dc.rights???: Acesso Aberto
???metadata.dc.rights.uri???: https://creativecommons.org/licenses/by-nc-nd/4.0/
URI: https://tede.ufam.edu.br/handle/tede/10011
Issue Date: 30-May-2023
Appears in Collections:Mestrado em Cirurgia

Files in This Item:
File Description SizeFormat 
DISS_KalineSilva_PPGRACI.pdf14.67 MBAdobe PDFThumbnail

Download/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.