Title: Otimização da metodologia para análise de selênio em água subterrânea usando espectrometria de emissão ótica com fonte de plasma indutivamente acoplado com gerador de hidretos (HG ICP OES)
???metadata.dc.creator???: Silva, Anny Karoliny Gonçalves da 
???metadata.dc.contributor.advisor1???: Oliveira, Tereza Crista Souza de
???metadata.dc.contributor.referee1???: Wiedmann, Larissa Silveira Moreira
???metadata.dc.contributor.referee2???: Nudi, Adriana Hadadd
???metadata.dc.description.resumo???: A quantidade de selênio no ambiente pode ocorrer naturalmente do intemperismo de rochas e solos, toda via, também é distribuído para o meio ambiente por atividades antropogênicas. Estando presente na água como selenato (+6) e selenito (+4). É um elemento essencial para a saúde humana ao mesmo tempo que em quantidade excessivas torna-se tóxico a saúde, o que torna de grande importância a determinação de selênio principalmente na água, fonte de selênio para o homem. Neste trabalho estão descritas as etapas de otimização da metodologia para determinação de selênio em água subterrânea, usando a técnica ICP OES juntamente com o gerador de hidretos (HG). A otimização foi elaborada considerando melhorias nas variáveis químicas, físicas e instrumentais do equipamento, aplicando-se um planejamento experimental fatorial 23 e logo em seguida a validação do método otimizado. Os testes foram realizados com o uso de padrões de referência (MRC) e amostras reais de matriz contendo selênio. As variações encontradas como ótimas foram: volume da alíquota 10ml da amostra para redução de Se(+6) para Se (+4), e 2mL para o agente pré-redutor (ácido clorídrico), redução do analito realizada em chapa aquecedora por 10 minutos á 80ºC volume e final de 25mL de amostra para análise no equipamento. Para o agente redutor (Borohidreto de sódio), manteve-se a concentração 0,5% em solução 0,2% de NaOH. Para condições instrumentais ficou definida como ideal a vazão do gás 0,3 L/min, para o tempo de limpeza do sistema de 75 segundos e vazão da amostra de 2,0 mL/min. Comparando-se os resultados obtidos com o método convencional de análise (nebulizador ultrassônico), nota-se grande vantagem da técnica HG-ICP OES e com grande viabilização do custo analítico, uma vez que a otimização permitiu uma economia de 50% nos reagentes, gases e amostras utilizados, bem como a redução de 50% no tempo de digestão e na quantidade resíduos gerados, levando a diminuição no desperdício de água e energia elétrica, sem que haja a perda da qualidade da análise e contribuindo para a preservação ambiental.
Abstract: The amount of selenium in the environment can occur naturally from the weathering of rocks and soils, however, it is also distributed to the environment by anthropogenic activities. Being present in water as selenate (+6) and selenite (+4). It is an essential element for human health although it becomes toxic to health in excessive amounts, which makes the determination of selenium quantities of great importance, especially in water, a source of selenium for man. This work describes the optimization steps of the methodology for the determination of selenium in groundwater, using ICP OES together with the hydride generator (HG). The optimization was elaborated considering improvements in chemical, physical, and instrumental variables, applying a planning experimental 23, and soon after the validation of the optimized method. Tests were performed using reference standards (MRC) and real matrix samples with concentrations containing selenium. The variations found to be optimal were: an aliquot volume of 10ml, and 2mL for the pre-reducing agent (hydrochloric acid); analyte reduction performed on a hot plate for 10 minutes at 80ºC, and a final volume of 25mL. For the reducing agent (Sodium borohydride), the concentration was maintained at 0.5%. For instrumental conditions, a gas flow of 0.3 L/min was defined as ideal, for a cleaning time of 75 seconds and a sample flow of 2.0 mL/min. Comparing the results obtained with the conventional method of analysis (ultrasonic nebulizer), a great advantage of the HG-ICP OES technique was noted and with great feasibility of the analytical cost, since the optimization allowed a savings of 50% in reagents, gases, and samples used, as well as a 50% reduction in digestion time and the amount of waste generated, leading to a reduction in the waste of water and electricity, without losing the quality of the analysis and contributing to environmental preservation.
???metadata.dc.subject.cnpq???: Ciências Exatas e da terra
???metadata.dc.subject.user???: Validação
Custo analítico
Água subterrânea
Language: por
???metadata.dc.publisher.country???: Brasil
Publisher: Universidade Federal do Amazonas
???metadata.dc.publisher.initials???: UFAM
???metadata.dc.publisher.department???: Instituto de Ciências Exatas
???metadata.dc.publisher.program???: Programa de Pós-graduação em Química
Citation: SILVA, Anny Karoliny Gonçalves da. Otimização da metodologia para análise de selênio em água subterrânea usando espectrometria de emissão ótica com fonte de plasma indutivamente acoplado com gerador de hidretos (HG ICP OES), 2022, 103 f., Dissertação (Mestrado em Química) - Universidade Federal do Amazonas, Manaus (AM), 2022.
???metadata.dc.rights???: Acesso Aberto
URI: https://tede.ufam.edu.br/handle/tede/9033
Issue Date: 6-May-2022
Appears in Collections:Mestrado em Química

Files in This Item:
File Description SizeFormat 
Dissertação_Anny Karoliny_PPGQ.pdf1.74 MBAdobe PDFThumbnail

Download/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.